Part Number Hot Search : 
51210 13VUQ LTC1277 090221 SSTPAD20 ENA1106 C1367 0309086
Product Description
Full Text Search
 

To Download HUS-0505 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 DC-DC Converter UNIT
HU Series ( 1.8 W UNREGULATED DC-DC CONVERTER )
FEATURES
1000VDC ISOLATION HIGH EFFICIENCY INTERNAL FILTERING LOW COST NO EXTERNAL COMPONENTS REQUIRED UP TO 1.8W UNREGULATED OUTPUT POWER DUAL IN LINE PACKAGE 100% BURNED IN LOW NOISE MTBF > 850,000 HOURS
OUTPUT SPECIFICATIONS
Voltage Setpoint Accuracy Temperature Coefficient Ripple & Noise (20MHz BW) Line Regulation1 Load Regulation
2
INPUT SPECIFICATIONS
+/-2% max +/-0.03%/ OC Input Voltage Range Input Filter +/-10% max Capacitor Type
100mVp-p max
+/-1.2% max +/-8% max Momentary
GENERAL SPECIFICATIONS
Efficiency Isolation Voltage
3
Short Circuit Protection
77%-85% 1000 VDC min 9 10 ohms min 25 KHz min 80pF max 850,000 Hours 10.1g Typ Non-Conductive Plastic 32.5mm*17mm*10.2mm
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature Storage Temperature Cooling -25 OC to +71 OC -55 OC to +125 OC Free-Air Convection
Isolation Resistance Switching Frequency Isolation Capacitance MTBF Weight
ALL SPECIFICATIONS TYPICAL AT NOMINAL LINE, FULL LOAD , AND 25
O
Case Material Case Size
C
UNLESS
OTHERWISE NOTED.
1 2 3
Line Regulation is for a 1.0% change in input Voltage. Load Regulation is for output load current change from 20% to 100%. For 60 seconds
www.Power-Systems.de
Page: 1 / 5
Version: 4-Oct-02
DC-DC Converter UNIT
HU Series ( 1.8 W UNREGULATED DC-DC CONVERTER )
SELECTION GUIDE 1.8W OUTPUT
MODEL NUMBER INPUT (VDC)
5
4
OUTPUT (VDC)
5 9 12 15 5 9 12 15 5 9 12 15 5 9 12 15
OUTPUT (mA)
360 200 150 120 360 200 150 120 360 200 150 120 360 200 150 120
INPUT CURRENT(mA)
FULL LOAD NO LOAD 40 40 38 38 18 18 16 16 9 9 9 8 5 5 5 5 77 77 80 81 78 81 81 82 79 82 83 85 78 81 81 82 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000
VOLTAGE VOLTAGE CURRENT
EFF (%)
ISOLATION (VDC)
HUS-0505 HUS-0509 HUS-0512 HUS-0515 HUS-1205 HUS-1209 HUS-1212 HUS-1215 HUS-2405 HUS-2409 HUS-2412 HUS-2415 HUS-4805 HUS-4809 HUS-4812 HUS-4815
5
467 476 450 444 192 185 185 182 95 92 90 88 48 46 46 45
5 5 5 12 12 12 12 24 24 24 24 48 48 48 48
Note: Other input to output voltages may be available. Please contact factory.
4 5
For LAN DC-DC CONVERTER For LAN DC-DC CONVERTER
www.Power-Systems.de
Page: 2 / 5
Version: 4-Oct-02
DC-DC Converter UNIT
HU Series ( 1.8 W UNREGULATED DC-DC CONVERTER )
MECHANICAL DIMENSIONS & RECOMMENDED FOOTPRINT DETAILS
PIN 1&24 2&23 10&15 11&14 12&13
SINGLE +Vin NC -Vout +Vout -Vin
SIMPLIFIED SCHEMATIC
+Vin
OSCILLATOR DRIVER
TYPICAL APPLICATIONS
INPUT OUTPUT
+Vin +Vout
+Vout
-Vin
-Vout
DC-DC CONVERTER
-Vin -Vout
LOAD
www.Power-Systems.de
Page: 3 / 5
Version: 4-Oct-02
DC-DC Converter UNIT
HU Series ( 1.8 W UNREGULATED DC-DC CONVERTER )
TYPICAL PERFORMANCE CUREVES
Specifications typical at ta=25 OC,nominal input voltage , rated output current unless otherwise specified.
VOUT VS LOAD(5Vout Models)
6.4 6.0
VOUT VS LOAD(9Vout Models)
10.4 10.0 9.6 9.2 8.8
Vout(V)
5.6 5.2 4.8 0 90 180 270 360
Vout(V)
0
50
100
150
200
Output Current(mA)
Output Current(mA)
VOUT VS LOAD(12Vout Models)
13.5 13.0
VOUT VS LOAD(15Vout Models)
16.5 16.0
Vout(V)
Vout(V)
12.5 12.0 11.5 0 38 75 112 150
15.5 15.0 14.5 0 30 60 90 120
Output Current(mA)
Output Current(mA)
EFFICIENCY VS LOAD
OUTPUT POWER(W) EFFICIENCY(%)
80.0 60.0 40.0 20.0 0.0 0 20 40 60 80 100 2.0 1.6 1.2 0.8 0.4 0.0
DERATING CURVE
SAFE OPERATING AREA
-25 0 25 50 70 100
% OF RATED LOAD(%)
TA(degree C)
www.Power-Systems.de
Page: 4 / 5
Version: 4-Oct-02
DC-DC Converter UNIT
HU Series ( 1.8 W UNREGULATED DC-DC CONVERTER )
HU SERIES APPLICATION NOTES:
EXTERNAL CAPACITANCE REQUIREMENTS: Output filtering is required for operation. A minimum of 10uF is needed. Output capacitance may be increased for additional filtering, not to exceed 220uF. To meet the reflected ripple requirements of the converter, an input impedance of less than 0.5 ohm from DC to 250KHz is required. Negative Outputs: A negative output voltage may be obtained by connecting the +OUT to circuit ground and connecting -OUT as the negative output.
FOR MORE INFORMATION CALL: Power Systems - The Power Solution
Ilsfeld-Auenstein ( Germany ) Dornet 8 E-mail: Info@Power-Systems.de Tel: + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 -80 Home Page: www.Power-Systems.de
www.Power-Systems.de
Page: 5 / 5
Version: 4-Oct-02


▲Up To Search▲   

 
Price & Availability of HUS-0505

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X